| Rated Battery Energy | 2.56kWh |
|---|---|
| Nominal Battery Voltage | 12.8V DC |
| Discharge Voltage Range | 10–14.4V DC |
| Standard Charging Current | 50A at 25°C |
| Maximum Charging / Discharging Current | 100A at 25°C |
| Cycle Life | 6,500 cycles at 80% DoD and 25°C |
| Charging Temperature | 0°C to 55°C |
| Discharging Temperature | −20°C to 55°C |
| Battery Storage Temperature | 20°C to 35°C |
| Nominal Input Voltage | 208 / 220 / 230 / 240V AC; L + N + PE |
|---|---|
| Input Frequency | 50 / 60Hz, auto-adaptive |
| Input Voltage Range — APP / GEN Mode | 90–280V AC |
| Input Voltage Range — UPS Mode | 170–264V AC |
| Rated Output Power | 1.2kW |
|---|---|
| Output Voltage | 208 / 220 / 230 / 240V AC |
| Power Factor | 1 |
| Output Frequency | 50 / 60Hz ±0.1% |
| Transfer Time | 10ms in APP / UPS / GEN mode |
| Output Waveform | Sine wave |
| Maximum Efficiency — Battery Mode | 90% at 12V DC |
| Overload Capacity — Battery Mode |
60 seconds at 102%–110% load; 10 seconds at 120%–200% load |
| Solar Charging Method | MPPT |
|---|---|
| Maximum PV Input Power | 800W |
| Maximum PV Input Current | 18A |
| MPPT Voltage Range | 17–115V DC |
| PV Start-up Voltage | 20V DC |
| Maximum PV Voltage | 115V DC |
| Maximum PV Charging Current | 50A |
| Maximum AC Charging Current | 50A |
| Maximum Combined Charging Current — PV + AC | 100A |
| Display | LCD |
|---|---|
| Communication Interface | RS232; optional RS485 and CAN |
| Monitoring | Optional Wi-Fi |
| Protection Rating | IP21 |
| Inverter Operating Temperature | −10°C to 60°C |
| Inverter Storage Temperature | −15°C to 60°C |
| Relative Humidity | 5%–95%, non-condensing |
| Maximum Operating Altitude | 4,000m; derating above 2,000m |
Battery temperature limits apply separately from inverter limits. Operate the complete system within the limits of all installed components. Cycle life depends on test conditions and actual use. Confirm the supplied configuration before ordering.