FH-8500
8.5kW
Rated capacity: 8.5kVA / 8.5kW
Maximum PV input: 10kW
PV array power: 5,000W × 2
Maximum charging current: 140A
Available in 8.5kW and 11kW models, the FLYFINE FH-8500 and FH-11000 combine DC-to-AC power conversion, MPPT solar charging and utility charging in one unit. Pure sine wave output supports solar power and backup applications built around a 48V battery system.
Both models feature a 60–450V DC MPPT operating range, RS485 lithium battery communication and an LCD display. Lithium batteries can be activated through PV or utility power, and independent operation without a battery is supported.
Rated capacity: 8.5kVA / 8.5kW
Maximum PV input: 10kW
PV array power: 5,000W × 2
Maximum charging current: 140A
Rated capacity: 11kVA / 11kW
Maximum PV input: 11kW
PV array power: 5,500W × 2
Maximum charging current: 160A
Provides 220/230/240V AC nominal output at 50/60Hz, with a listed peak efficiency of 94%.
Supports a 60–450V DC MPPT range and a maximum PV open-circuit voltage of 500V DC.
RS485 communication supports integration with compatible lithium battery systems. Battery activation is available through solar or utility power.
An integrated LCD provides access to operating information. Transfer time is listed as 10ms in PC mode and 20ms in Home mode.
| Parameter | FH-8500 | FH-11000 |
|---|---|---|
| Rated Capacity | 8.5kVA / 8.5kW | 11kVA / 11kW |
| Maximum PV Input Power | 10kW | 11kW |
| PV Array Power | 5,000W × 2 | 5,500W × 2 |
| Surge Power | 17,000VA | 22,000VA |
| Maximum Battery Discharge Current | 180A | 220A |
| Maximum Solar Charge Current | 140A | 160A |
| Maximum AC Charge Current | 120A | 120A |
| Maximum Charging Current | 140A | 160A |
| Net Weight | 14kg | 15kg |
| Battery Voltage | 48V DC |
|---|---|
| Nominal AC Input Voltage | 230V AC |
| AC Input Voltage Range | 170–280V AC (PC); 110–280V AC (Home) |
| AC Input Frequency | 50/60Hz, adaptive |
| Nominal AC Output Voltage | 220/230/240V AC |
| Output Frequency | 50/60Hz |
| Output Waveform | Pure sine wave |
| Transfer Time | 10ms (PC); 20ms (Home) |
| Peak Efficiency | 94% |
| Solar Charger Type | MPPT |
| MPPT Voltage Range | 60–450V DC |
| Maximum PV Open-Circuit Voltage | 500V DC |
| Maximum Solar Input Current | 18A × 2 |
| Floating Charge Voltage | 54V DC |
| Overcharge Protection | 63V DC |
| Charging Method | CC/CV |
| Lithium Battery Activation | Supported through PV or utility power |
| Communication Interfaces | RS485 / dry contact |
| Display | LCD |
| Parallel Operation | Not supported |
| Dimensions | 540 × 415 × 122mm |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −15°C to +50°C |
| Relative Humidity | 5–95%, non-condensing |
Specifications are based on the FLYFINE FH-8500 / FH-11000 datasheet. Product images are for reference. Confirm the configuration and specifications for your order with FLYFINE.
Select the model according to continuous load, starting demand, PV string configuration and battery discharge capability. Confirm battery communication compatibility before ordering.
The FH-8500 provides 8.5kW rated output and accepts up to 10kW of PV input. The FH-11000 provides 11kW rated output and accepts up to 11kW of PV input. Their maximum charging currents are 140A and 160A respectively.
Both models use a nominal 48V DC battery system and support RS485 lithium battery communication. Confirm the battery operating voltage, current ratings and communication protocol with FLYFINE when selecting a battery.
The product brochure lists independent operation without a battery. Confirm the required PV supply and load conditions for your installation with FLYFINE.
No. Parallel operation is not supported for the FH-8500 and FH-11000 models listed in this datasheet.
Open the FH-8500 / FH-11000 datasheet for the original technical specification table.